The 124A Series™ internal gear pump is the ideal solution for adhesives, paints & inks, polymers, and more because of the broad range of available designs and other options. It can handle flows up to 500 GPM (114 m³/h).
Features & Benefits
- Rugged and reliable, yet economical
- Widest range of sizes and options available to suit almost any non-corrosive application
- Tightest clearances for high efficiency and excellent priming capability
Capacity
0 to 500 GPM
1 to 114 m³/h
Viscosity
28 to 2,000,000 SSU
1 to 440,000 cSt
Pressure
to 200 PSI
to 14 Bar
Temperature
-60 to +450 °F
-51 to +230 °C
Options
Porting
Drives
Mounting
Sealing
Specifications
| Model | Standard Port Size | Nominal Pump Rating (GPM) | Nominal Pump Rating (m3/h) | Maximum RPM | Maximum Pressure PSI | Maximum Pressure BAR |
|---|---|---|---|---|---|---|
| G124A | 1 | 8 | 1.8 | 1750 | 200 | 14 |
| H124A | 1.5 | 15 | 2.8 | 1750 | 200 | 14 |
| HL124A | 1.5 | 30 | 5.6 | 1750 | 200 | 14 |
| AK124A | 2 | 67 | 15 | 1450 | 200 | 14 |
| AL124A | 2 | 90 | 20 | 1450 | 200 | 14 |
| K124A | 2 | 80 | 18 | 780 | 200 | 14 |
| KK124A | 2 | 100 | 23 | 780 | 200 | 14 |
| L124A | 2 | 135 | 31 | 640 | 200 | 14 |
| LQ124A | 2.5 | 135 | 31 | 640 | 200 | 14 |
| LL124A | 3 | 140 | 32 | 520 | 200 | 14 |
| LS124A | 3 | 200 | 45 | 640 | 200 | 14 |
| Q124A | 4 | 300 | 68 | 520 | 200 | 14 |
| QS124A | 6 | 500 | 114 | 520 | 200 | 14 |
| M124A | 4 | 420 | 95 | 420 | 200 | 14 |
Videos
Adhesives
Adhesives are a group of substances, such as cement, glue, mucilage, and paste that are capable of holding materials together by surface attachment. Adhesives are made from many different basic materials, among them dextrin, latex, silicones, liquid rubber, resin, sodium silicate, and starch.
Asphalt Cement
Clean asphalt contains no fillers and is an oil based liquid. It is primarily used in paving roads, waterproofing liquids, and paints. Typically they are handled at elevated temperatures to reduce the viscosity of the asphalt. The pump needs a source of heat like jacketing or electric heat to prevent the product from solidifying in the pump.
Asphalt Emulsions
Emulsions are asphalt suspended in a mixture with water or other liquids. This is done to ease the application of the asphalt. Uses would be crack filling, coating roadways, or waterproofing. These emulsions are shear sensitive and must be handled with care.
Filled Asphalt
Filled asphalts contain particulate used in the liquids’ end applications. Examples of this would be roofing materials and hot mix plants. Typically they are handled at elevated temperatures to reduce the viscosity of the asphalt mixture. The pump needs a source of heat like jacketing or electric heat to prevent the product from solidifying in the pump.
Paints
Paints are shear sensitive liquids that can have a variety of solvents & pigment load concentrations that bring with them abrasive wear and chemical compatibility concerns.
Technical Service Manuals
Technical Service Manuals
Technical Service Manuals
Catalog Sections
Catalog Sections
Catalog Sections
Product Flyers
Product Flyers
Product Flyers
Product Flyers
Product Flyers
Application Flyers
Application Flyers
Application Flyers
Application Flyers
Application Flyers
Application Flyers
Application Flyers
Application Flyers
Application Flyers
Application Flyers
Application Flyers
Application Flyers
Application Flyers
Application Flyers
Application Flyers
Application Flyers
Application Flyers
Application Flyers
Application Flyers
Application Flyers
Application Flyers
Application Flyers
Application Flyers
Application Flyers
Application Flyers
-
REPAIR RESOURCES
-
DRAWINGS
AK-AL with Plain Head - 2" NPT RH PDF
AK-AL with Relief Valve - 2" NPT RH PDF
G with Plain Head - 1" NPT RH PDF
G with Relief Valve - 1" NPT RH PDF
H-HL with Plain Head - 1.5" NPT RH/LH PDF
H-HL with Relief Valve - 1.5" NPT RH/LH PDF
H-HL8124A with Relief Valve - 1.5" NPT RH/LH PDF
H-HLwith Plain Head - 1.5" NPT RH/LH PDF
K-KK with Plain Head - 2" NPT RH PDF
K-KK with Plain Head - 2" NPT RH/LH PDF
K-KK with Relief Valve - 2" NPT RH/LH PDF
K-KK8124A with Relief Valve - 2" NPT RH/LH PDF
L with Plain Head - 2" NPT RH PDF
L with Relief Valve - 2" NPT RH PDF
L8124A with Plain Head - 2" NPT RH/LH PDF
L8124A with Relief Valve - 2" NPT RH/LH PDF
LL with Plain Head - 3" Class 125 ANSI RH/LH PDF
LL with Plain Head - 3" Class 125 ANSI RH/LH PDF
LL with Relief Valve - 3" Class 125 ANSI RH PDF
LL with Relief Valve - 3" Class 125 ANSI RH PDF
LQ with Plain Head - 2.5" Class 125 ANSI RH/LH PDF
LQ with Plain Head - 2.5" Class 125 ANSI RH/LH PDF
LQ with Relief Valve - 2.5" Class 125 ANSI RH/LH PDF
LQ with Relief Valve - 2.5" Class 125 ANSI RH/LH PDF
LS with Plain Head - 3" Class 125 ANSI RH/LH PDF
LS with Plain Head - 3" Class 125 ANSI RH/LH PDF
LS with Relief Valve - 3" Class 125 ANSI RH PDF
LSwith Relief Valve - 3" Class 125 ANSI RH/LH PDF
M with Plain Head - 4" Class 125 ANSI RH PDF
M with Relief Valve - 4" Class 125 ANSI RH PDF
Q with Relief Valve - 4" Class 125 ANSI RH/LH PDF
Q with Relief Valve - 4" Class 150 ANSI RH/LH with Studs and Bolts PDF
QS with Plain Head - 4" Class 125 ANSI RH/LH PDF
QS with Plain Head - 6" Class 125 ANSI Opposite PDF
QS with Relief Valve - 6" Class 125 ANSI Opposite PDF
QS with Relief Valve - 6" Class 150 ANSI Opposite PDF
QS with Relief Valve - 6" Class 150 ANSI RH PDF