The 1224C-BXB Series™ jacketed internal gear pump is part of Viking Pump’s Liquid Specific Product Line. It features the O-Pro® Barrier Seal, making it an ideal solution for demanding applications such as starch and adhesives, where mechanical seals often fail and traditional packing can leak and create cleanup issues. It can handle flows up to 200 GPM (45 m³/h).
Features & Benefits
- O-Pro® Barrier Seal to prevent process liquid from leaking
- Jacketed chambers allow effective control of product temperature in applications requiring thermal management
- U-Plus™ Bracket which can accommodate seal options beyond the standard O-Pro® Barrier seal such as packing, single component seals (stuffing box or behind the rotor), cartridge lip seals, and single or double cartridge seals
- Optional ProPort™ Casing to accommodate a variety of port sizes and types to simply integration into existing piping systems
Capacity
8 to 200 GPM
1.8 to 45 m³/h
Viscosity
100 to 2,000,000 SSU
20 to 440,000 cSt
Pressure
200 PSI
14 BAR
Temperature
0 to +350°F
-15 to +175°C
Options
Porting
Drives
Mounting
Sealing
Specifications
| Model | Standard Port Size | Nominal Pump Rating (GPM) | Nominal Pump Rating (m3/h) | Maximum RPM | Maximum Pressure PSI | Maximum Pressure BAR |
|---|---|---|---|---|---|---|
| H1224C-BXB | 1.5 | 8 | 1.8 | 1000 | 200 | 14 |
| HL1224C-BXB | 1.5 | 18 | 4 | 1000 | 200 | 14 |
| K1224C-BXB | 2 | 80 | 18 | 780 | 200 | 14 |
| KK1224C-BXB | 2 | 100 | 23 | 780 | 200 | 14 |
| L1224C-BXB | 2 | 135 | 31 | 640 | 200 | 14 |
| LL1224C-BXB | 3 | 140 | 32 | 520 | 200 | 14 |
| LS1224C-BXB | 3 | 200 | 45 | 640 | 200 | 14 |
Videos
Starch Adhesive
Starch based adhesives are used in the paper and corrugating industries. The raw starch is derived from a variety of plants such as corn, wheat, and potatoes. They tend to be shear sensitive (thickening) and are mixed in equipment commonly referred to as a starch kitchen.
-
REPAIR RESOURCES
How to Set End Clearance on a Viking Pump Quick Tip: Change Port Sizes or Types with ProPort™ Casing Quick Tip: Modifying Window Guards on a Viking Pump with U-Plus™ Bracket
-
DRAWINGS
H-HL with Jacketed Head - 1.5" NPT RH/LH PDF
STEP
H-HL with Jacketed Head and ProPort Casing - 1.5" Class 125 ANSI RH/LH PDF
STEP
H-HL with Jacketed Head and ProPort Casing - 1.5" NPT RH/LH PDF
STEP
H-HL with Jacketed Head and ProPort Casing - 2" Class 150 ANSI RH/LH PDF
STEP
H-HL with Jacketed Head and ProPort Casing - 2" Class 300 ANSI RH/LH PDF
STEP
H-HL with ProPort Casing - 1.5" Class 250 ANSI RH/LH PDF
STEP
H-HL with Relief Valve - 1.5" NPT RH/LH PDF
STEP
H-HL with RV and ProPort Casing - 1.5" Class 125 ANSI RH/LH PDF
STEP
H-HL with RV and ProPort Casing - 1.5" Class 250 ANSI RH/LH PDF
STEP
H-HL with RV and ProPort Casing - 1.5" NPT RH/LH PDF
STEP
H-HL with RV and ProPort Casing - 2" Class 150 ANSI RH/LH PDF
STEP
H-HL with RV and ProPort Casing - 2" Class 300 ANSI RH/LH PDF
STEP
K-KK with Jacketed Head - 2" NPT RH/LH PDF
STEP
K-KK with Jacketed Head - 4" Class 125 ANSI RH/LH PDF
STEP
K-KK with Jacketed Head and ProPort Casing - 2" Class 125 ANSI RH/LH PDF
STEP
K-KK with Jacketed Head and ProPort Casing - 2" Class 250 ANSI RH/LH PDF
STEP
K-KK with ProPort Casing - 2" NPT RH/LH PDF
STEP
K-KK with ProPort Casing - 3" Class 150 ANSI RH/LH PDF
STEP
K-KK with ProPort Casing - 3" Class 300 ANSI RH/LH PDF
STEP
K-KK with Relief Valve - 2" NPT RH/LH PDF
STEP
K-KK with Relief Valve - 4" Class 125 ANSI RH/LH PDF
STEP
K-KK with RV and ProPort Casing - 2" Class 125 ANSI RH/LH PDF
STEP
K-KK with RV and ProPort Casing - 2" Class 250 ANSI RH/LH PDF
STEP
K-KK with RV and ProPort Casing - 2" NPT RH/LH PDF
STEP
K-KK with RV and ProPort Casing - 3" Class 150 ANSI RH/LH PDF
STEP
K-KK with RV and ProPort Casing - 3" Class 300 ANSI RH/LH PDF
STEP
L with Jacketed Head - 2" NPT RH/LH PDF
STEP
L with Jacketed Head and ProPort Casing - 2.5" Class 125 ANSI RH/LH PDF
STEP
L with Jacketed Head and ProPort Casing - 2.5" Class 250 ANSI RH/LH PDF
STEP
L with Jacketed Head and ProPort Casing - 3" Class 125 ANSI RH/LH PDF
STEP
L with Jacketed Relief Valve - 2" NPT RH/LH PDF
STEP
L with Jacketed RV and ProPort Casing - 2" NPT RH/LH PDF
STEP
L with Jacketed RV and ProPort Casing - 2.5" Class 125 ANSI RH/LH PDF
STEP
L with Jacketed RV and ProPort Casing - 2.5" Class 250 ANSI RH/LH PDF
STEP
L with Jacketed RV and ProPort Casing - 3" Class 125 ANSI RH/LH PDF
STEP
L with Jacketed RV and ProPort Casing - 3" Class 250 ANSI RH/LH PDF
STEP
L with Jacketed RV and ProPort Casing - 4" Class 150 ANSI RH/LH PDF
STEP
L with Jacketed RV and ProPort Casing - 4" Class 300 ANSI RH/LH PDF
STEP
L with ProPort Casing - 2" NPT RH/LH PDF
STEP
L with ProPort Casing - 3" Class 250 ANSI RH/LH PDF
STEP
L with ProPort Casing - 4" Class 150 ANSI RH/LH PDF
STEP
L with Relief Valve - 2" NPT RH/LH PDF
STEP
L with RV and ProPort Casing - 2" NPT RH/LH PDF
STEP
L with RV and ProPort Casing - 2.5" Class 125 ANSI RH/LH PDF
STEP
L with RV and ProPort Casing - 2.5" Class 250 ANSI RH/LH PDF
STEP
L with RV and ProPort Casing - 3" Class 125 ANSI RH/LH PDF
STEP
L with RV and ProPort Casing - 3" Class 125 ANSI RH/LH PDF
STEP
L with RV and ProPort Casing - 3" Class 250 ANSI RH/LH PDF
STEP
L with RV and ProPort Casing - 4" Class 150 ANSI RH/LH PDF
STEP
LL with Jacketed Head - 3" Class 125 ANSI RH/LH PDF
STEP
LL with Jacketed Head and ProPort Casing - 3" Class 125 ANSI RH/LH PDF
STEP
LL with Jacketed Head and ProPort Casing - 3" Class 250 ANSI RH/LH PDF
STEP
LL with Jacketed Relief Valve - 3" Class 125 ANSI RH/LH PDF
STEP
LL with Jacketed RV and ProPort Casing - 3" Class PDF
STEP
LL with Jacketed RV and ProPort Casing - 3" Class 250 ANSI RH/LH PDF
STEP
LL with Jacketed RV and ProPort Casing - 4" Class 150 ANSI RH/LH PDF
STEP
LL with Jacketed RV and ProPort Casing - 4" Class 300 ANSI RH/LH PDF
STEP
LL with ProPort Casing - 4" Class 150 ANSI RH/LH PDF
STEP
LL with ProPort Casing - 4" Class 300 ANSI RH/LH PDF
STEP
LL with Relief Valve - 3" Class 125 ANSI RH/LH PDF
STEP
LL with Relief Valve - 3" Class 125 ANSI RH/LH PDF
STEP
LL with RV and ProPort Casing - 3" Class 125 ANSI RH/LH PDF
STEP
LL with RV and ProPort Casing - 3" Class 250 ANSI RH/LH PDF
STEP
LL with RV and ProPort Casing - 4" Class 150 ANSI RH/LH PDF
STEP
LL with RV and ProPort Casing - 4" Class 300 ANSI RH/LH PDF
STEP
LS with Jacketed Head and ProPort Casing - 3" Class 125 ANSI RH/LH PDF
STEP
LS with Jacketed Head - 3" Class 125 ANSI RH/LH PDF
STEP
LS with Jacketed Head and ProPort Casing - 3" Class 250 ANSI RH/LH PDF
STEP
LS with Jacketed Head and ProPort Casing - 4" Class 125 ANSI RH/LH PDF
STEP
LS with Jacketed Relief Valve - 3" Class 125 ANSI RH/LH PDF
STEP
LS with Jacketed RV and ProPort Casing - 3" Class 125 ANSI RH/LH PDF
STEP
LS with Jacketed RV and ProPort Casing - 3" Class 250 ANSI RH/LH PDF
STEP
LS with Jacketed RV and ProPort Casing - 4" Class 150 ANSI RH/LH PDF
STEP
LS with Jacketed RV and ProPort Casing - 4" Class 300 ANSI RH/LH PDF
STEP
LS with ProPort Casing - 3" Class 250 ANSI RH/LH PDF
STEP
LS with ProPort Casing - 4" Class 300 ANSI RH/LH PDF
STEP
LS with Relief Valve - 3" Class 125 ANSI RH/LH PDF
STEP
LS with RV and ProPort Casing - 3" Class 125 ANSI RH/LH PDF
STEP
LS with RV and ProPort Casing - 3" Class 250 ANSI RH/LH PDF
STEP
LS with RV and ProPort Casing - 3" Class 250 ANSI RH/LH PDF
STEP
LS with RV and ProPort Casing - 4" Class 125 ANSI RH/LH PDF
STEP
LS with RV and ProPort Casing - 4" Class 250 ANSI RH/LH PDF
STEP
One Pump. Endless Configurations. Zero Compromises.
Viking's Next Generation Universal pumps use modular design to give you more options with fewer parts reducing your inventory complexity.
Viking Pump's U-Plus™ Bracket
-
Accepts a variety of seal types to meet your needs
-
Stainless steel window guards offer protection from rotating parts
-
Footed one-piece iron bracket provides rigid mounting to help maintain alignment, which extends seal and bearing life
Viking Pump's ProPort™ Casing
-
Adaptable port design offers a variety of port sizes and types, simplifying integration into existing piping systems and enhances installation efficiency
-
H-Q sizes available with optional opposite porting
-
Casing drain allows the pump to be drained without removing the head
-
Optional O-ring joint seals for high pressure of difficult to seal applications