Altura de succión positiva neta

Altura de succión positiva neta

Glossary Right Side Image
Imagen de una bomba con manómetro de entrada y salida
Abbreviation / Acronym
NPSH
Classification
Definition

La altura absoluta necesaria en la entrada de la bomba para evitar la cavitación, indicada con el sufijo «A» para la altura disponible en el sistema o «R» para la altura requerida por la bomba. Similar a NPIP.

Understanding net positive suction head (NPSH)

NPSHA is a function of your system and must be calculated, whereas NPSHR is a function of the pump and must be provided by the pump manufacturer. NPSHA MUST be greater than NPSHR for the pump system to operate without cavitating. You must have more suction side pressure available than the pump requires or cavitation will occur.

What is cavitation?

Pump cavitation occurs when the pressure at the pump inlet drops below the vapor pressure of the liquid. Vapor bubbles form at the inlet of the pump and are moved to the outlet where they collapse, often taking small pieces of the pump with them.

Cavitation is often characterized by:

  1. Loud noise often described as a grinding or “marbles” in the pump
  2. Loss of capacity (bubbles are now taking up space where liquid should be)
  3. Pitting damage to parts as material is removed by the collapsing bubbles

To learn more, watch this video about cavitation.