Section
Capacidad
10 GPM
2.3 m³/h
Viscosidad
28 a 2,000,000 SSU
0.1 a 440,000 cSt
Presión
150 PSI
10 BAR
Temperatura
0 a +350°F
-15 a +175°C
Opciones
Puertos
NPT
Embridada (compatible con ASME/ANSI o DIN)
Ángulo derecho (90°)
Opuesto (180°)
Transmisores
Reductor motriz R de engranaje con compensación
Reductor motriz P de engranaje adquirido
Transmisor D montado directamente
Montaje
Montaje de pie
Sellado
Sello O-Pro® Guard
TSM / Catalog / Flyers / Brochures
-
REPAIR RESOURCES
How to Set End Clearance on a Viking Pump Quick Tip: How to install an O-Pro® Cartridge seal into a Viking pump Replacing a Behind the Rotor Seal - 4127C & 4227C Series™ Converting a Pump from Packing to O-Pro® Cartridge Seal in Pumps with a U-Plus™ Bracket How to replace o-rings in an O-Pro® Guard seal Quick Tip #01 - Setting End Clearance on a Viking Pump Universal Seal Pump Converting a Pump from Packing to O-Pro® Guard Seal in Pumps with a U-Plus™ Bracket Quick Tip: How to install an O-Pro® Guard seal into a Viking pump Quick Tip: Modifying Window Guards on a Viking Pump with U-Plus™ Bracket Replacing Packing - 127C & 227C Series™ How to Use a Thrust Bearing Locknut Tool Quick Tip: Swap between fiber gaskets and o-rings with the ProPort™ casing Quick Tip: Change Port Sizes or Types with ProPort™ Casing Viking Pump Universal Seal Series with Stuffing Box Component Seals Repair Kit Installation Quick Tip #02 - Install Mechanical Seal into Stuffing Box in Viking Pump Universal Seal Pump How to replace o-rings in an O-Pro® Cartridge seal Replace Stuffing Box Mechanical Seal - 4127C & 4227C Series™
-
DRAWINGS
H1227C with Jacketed Head - 1.5" Class 150 ANSI Opposite PDF
H1227C with Jacketed Head - 1.5" Class 150 ANSI RH/LH PDF
STEP
H1227C with Jacketed Head - 1.5" Class 300 ANSI Opposite PDF
H1227C with Jacketed Head - 1.5" Class 300 ANSI RH/LH PDF
STEP
H1227C with Jacketed Head - 1.5" NPT Opposite PDF
H1227C with Jacketed Head - 1.5" NPT RH/LH PDF
STEP
H1227C with Jacketed Head - 2" Class 150 ANSI Opposite PDF
H1227C with Jacketed Head - 2" Class 150 ANSI RH/LH PDF
STEP
H1227C with Jacketed Head - 2" Class 300 ANSI Opposite PDF
H1227C with Jacketed Head - 2" Class 300 ANSI RH/LH PDF
STEP
H1227C with Jacketed Head - DIN 32 PN16 (RF) Opposite PDF
H1227C with Jacketed Head - DIN 40 PN16 Opposite PDF
H1227C with Jacketed Head - DIN 50 PN16 Opposite PDF
H1227C with Plain Head - DIN 32 PN16 RH/LH PDF
H1227C with Plain Head - DIN 40 PN16 RH/LH PDF
H1227C with Plain Head - DIN 50 PN16 RH/LH PDF
H1227C with Relief Valve - 1.5" Class 150 ANSI Opposite PDF
H1227C with Relief Valve - 1.5" Class 150 ANSI RH/LH PDF
STEP
H1227C with Relief Valve - 1.5" Class 300 ANSI Opposite PDF
H1227C with Relief Valve - 1.5" Class 300 ANSI RH/LH PDF
STEP
H1227C with Relief Valve - 1.5" NPT Opposite PDF
H1227C with Relief Valve - 1.5" NPT RH/LH PDF
STEP
H1227C with Relief Valve - 2" Class 150 ANSI Opposite PDF
H1227C with Relief Valve - 2" Class 150 ANSI RH/LH PDF
STEP
H1227C with Relief Valve - 2" Class 300 ANSI Opposite PDF
H1227C with Relief Valve - 2" Class 300 ANSI RH/LH PDF
STEP
H1227C with Relief Valve - DIN 32 PN16 (RF) Opposite PDF
H1227C with Relief Valve - DIN 32 PN16 RH/LH PDF
H1227C with Relief Valve - DIN 40 PN16 Opposite PDF
STEP
H1227C with Relief Valve - DIN 40 PN16 RH/LH PDF
H1227C with Relief Valve - DIN 50 PN16 Opposite PDF
H1227C with Relief Valve - DIN 50 PN16 RH/LH PDF
H-HL1227C with Relief Valve - DIN 50 PN16 Opposite PDF